OBSERVATIONS
OF SNOW STRUCTURE
by
R. Perla
National Hydrology Research Institute
Box 313 Canmore, Alberta TOLOMO Canada
and
J. Dozier
Department of Geography, University of
California, Santa Barbara, CA., 93106
September 1984
ABSTRACT
Two methods are used to study snow structure. The thin-section method produces
high contrast photomicrographs and information on crystal orientation and boundaries, but
it is a slow and tedious method. The section-plane method is much faster and can
be used to prepare a large number of adjacent parallel planes (serial sections) through a
sample in order to describe the three-dimensional interconnection of the phases.
Photomicrographs of section planes can be converted to video format, digitized, and
analyzed on a desk computer.
INTRODUCTION
The structure of snow consists of two interconnecting. phases, ice and pore space (gas),
and sometimes a third phase, liquid water. This paper is mostly limited to methods for
observing the structure of cold, dry snow(ice and pore). The problem of observing all
three phases is taken up only briefly in the last section.
The ice phase can be idealized as a complex assembly of polyhedra, tubes, plates, spheres,
needles, and shells. Figure 1 illustrates three very simplified idealizations: an assembly
of polyhedra (top); an assembly of tubes (middle); and a combination of polyhedra and
tubes (bottom). Figure 1 is an attempt to represent older snow that has recrystallized and
sintered. Newly fallen snow is better represented by a connected system of delicate cloud
forms: such as needles, plates, and dendrites.
Snow is characterized by connectivity of the pore space. Pore connectivity decreases as
density increases. At some high density near 800 kg /m3 the structure consists of isolated
pore bubbles, and can be called ice rather than snow.
All snow properties pertinent to engineering and hydrologic problems depend on snow
structure. Density is an example of a simple and useful measure of structure; however, it
is an incomplete measure.-The thermal conductivity of snow, the strength of snow, and the
response of snow to the electromagnetic spectrum are examples of properties that are
crucially determined by the spatial distribution of the phases, as well as by the density.
Figure 1.--Three
simple idealizations of
snow structure.
DISAGGREGATION OF STRUCTURE
Figure 2 illustrates three methods for microscopic observation of snow. The simplest
method is to disaggregate the structure into individual grains which can be studied under
a magnifying glass, microscope, or macroscope using incident reflected light or
transmitted polarized light as shown in figure 2 left. This yields important qualitative
information on crystal morphology, and possibly some quantitative indices such as maximum
crystal size. It is a quick and practical field method, and at present it is probably the
only feasible method for classifying snow in operational hydrology, avalanche forecasting,
ski area management, ski racing, or whenever one needs to be specific about snow crystal
morphology. However, disaggregation destroys the structure and any hope for obtaining
fundamental predictors of snow properties.
Figure 2.--Three
methods for microscopic observation of snow. The image may be
captured with a photomacroscope (as shown), photomicroscope, video camera, etc.
THIN-SECTIONS
There are two known methods for observing snow structure: the method of thin-sections
(fig. 2 centre); and the method of section-planes (fig. 2 right). Both are
research tools that so far have not been used operationally in snow studies. Preparation
of thin-sections involves the following steps:
*The pore space of a snow sample is filled with a supercooled, water insoluble liquid.
*The liquid is frozen solid.
* A small block is sawed off from the sample and mounted in a microtome.
* A flat surface is shaved.
* This flat surface is bonded to a glass slide.
* The glass slide is fixed in the microtome (e.g. held by vacuum suction on a preshaved
plane of ice or wax) such that the microtome knife can shave planes
parallel to the glass slide -- alignment is critical.
* Successive shaves are performed until the desired thin-section thickness is obtained
~10um to ~100um).
* The thin-section is photographed using transmitted polarized light.
* Contrast is improved if the water insoluble filler is melted back to a liquid (or
dissolved chemically).
The above steps are more fully described by Kinosita and Wakahama (1960). Transmitted,
polarized diffuse light provides information on crystal boundaries and orientation, and
produces high contrast photomicrographs that can be analyzed manually as described by
Fuchs (1959) or converted to video format and digitized (Good, 1979, 1980, 1981, 1982).
Unfortunately, the method of thin-sections (as presently followed) has certain
disadvantages:
* It is a time consuming method limited to a few sections per day per person.
* Structural parameters depend critically on the section thickness (Keeler 1969).
* The method (at least based on the above steps) does not lend itself to the preparation
of adjacent parallel sections through a sample.
However, technological breakthroughs could remedy the above disadvantages.
SECTION-PLANES
A simpler and faster alternative is to prepare a single plane surface for photomicrography
using incident reflected light (fig. 2 right) in accordance with techniques described by
Narita (1969), Kry (1975), and Perla (1982). The preparation of the sample block for
microtoming follows the initial three or four steps used to prepare a thin-section.
However, it is very important to dye the pore filler to dark blue or red for a reason to
be explained shortly.
* Place a small snow sample with approximate cubical dimensions 25mm x 25mm x 25mm into a
small cardboard box, which is cut and taped together to dimensions larger than the snow
sample but small enough to fit into the microtome clamp.
* Slowly fill the box with the dyed pore filler until the snow cube is completely
saturated. Note: If the snow sample is too large it may not be possible to completely
saturate its interior.
* Use dry ice particles to initiate freezing of the filler; complete the freezing by
storing the sample in a freezer (below - 20 degrees C) for several hours.
* Saw the cardboard box in half, and mount the bottom half in a microtome.
* Make several large cuts, and then some smaller finishing cuts with a clean knife. In
between cuts, the microtome knife and the sample surface are vacuum cleaned. The cutting
will be smoother if (in the above step) a thin rim of cardboard is removed from around the
perimeter of the section so that the knife does not scrape the cardboard edge.
* The sample is removed from the microtome, and allowed to stand for about 5 minutes at
-10 degrees C to -5 degrees C during which time the ice profiles in the section plane will
sublimate (etch) back from the filler.
* The section-plane is polished very gently with lens tissue.
* A light dusting of fingerprint powder is applied to the section-plane with a cotton
swab, and gently polished with lens tissue.
The Appendix provides a list of equipment and supplies needed to prepare section planes.
Figure 3 illustrates the basic steps which are performed in a refrigerated laboratory (-5
degrees C to -10 degrees C).
Figure 3.--Preparation
of a section-plane in
a snow sample.
PHOTOMICROGRAPHY AND ANALYSIS
The last steps are repeated one or two times until contrast appears adequate for
photomicrography. To obtain optimum contrast using incident reflected light, it is
important that the tight source and the objective tens of the microscope (or macroscope)
be raised as high as possible above the section-plane, that is, the "working
distance" (objective to stage) should be as high as possible; this can be achieved by
adding a 0.5X objective lens. The high working distance minimizes the amount of obliquely
scattered light that enters the objective. It is also essential to dye the pore filler.
Contrary to what may be expected, a dark filler insures that the transparent ice profiles
appear much darker than the filler (the analogy is looking through a window into a room
with dark walls).
Section-plane preparation is far simpler and quicker than thin-section preparation. The
resulting "mathematical plane" can be analyzed using well-developed formalisms
from the field of stereology (Weibel 1979, 1980). Section thickness does not enter into
the problem, and thus a major disadvantage of the thin-section technique is avoided.
On the other hand, the section-plane technique (using present technology) provides no
information on orientation of crystal axes, and very little, if any, information on
crystal boundaries. Perhaps future improvements in the preparation technique could
accentuate crystal boundaries.
SERIAL SECTIONS
The technique of serial sections (De Hoff 1983) involves cutting successive,
parallel planes down through the sample at sufficiently close intervals ( ~10 um to ~100
um ) so that a three-dimensional model can be constructed by correlating ice profiles as
illustrated in figure 4, adapted from Steele (1972).
In order to cut the large number of parallel section-planes, (50 to 150) that are required
to characterize the structure, it seems essential that the photomacroscope be mounted
directly over the microtome because alignment with the knife will be disturbed if the
sample is removed from the microtome for photomicrography and then replaced in the
microtome. Alignment with the objective plane of the photomacroscope is not very critical;
it is only necessary that 2 or 3 reference points be established in the section (e.g.
toothpicks can be inserted in the snow cube before the filler is poured). The
photomacroscope can be mounted on a frame which is brought into position over the
microtome (figure 5).
Figure 4.--Correlation
of ice profiles on two parallel
section-planes. Adapted from Steele (1972).
It can be understood that modeling the three-dimensional structure of snow is a
challenging and perhaps tedious experimental and theoretical problem, but without some
measure of snow topology and/or geometry a systematic treatment of fundamental snow
properties will remain elusive.
Figure 5.--Arrangement
for preparing and photographing
serial sections. The photomacroscope is supported on
a frame over a microtome.
VIDEO DIGITIZING
In order to analyze mathematically the -100 serial sections, it is first necessary to
convert the photomicrographs into digital format. Walter Good (1979, 1980, 1981, 1982)
demonstrated that thin-section images (photomicrographs or real-time imagery with
transmitted light) can be captured to a sufficient level of contrast and resolution with a
video camera to allow digital processing. Sommerfeld (1983) used digitized data from
thin-sections to study snow metamorphism.
The contrast and resolution of section-plane photomicrographs are not as good as
thin-section images; however, if the recommended preparation steps are followed the
majority of section-plane photomicrographs will have high enough quality for digital
processing.
Reasonable results were obtained using the relatively low-cost equipment diagramed in
figure 6. The photomicrograph in the form of a 35 mm colour slide transparency is inserted
in a video adapter (Sony video photolab adapter HVT 3000), converted to a video signal
using a Sony HVC-2800 video camera, and digitized in an IBM PC by a video digitizing card
(Tecmar's "Video Van Gough"). The digitized image consisted of 240 x 250 =
60,000 pixels. Each pixel is characterized by an 8 bit (0 = 255) brightness level. Similar
equipment was used effectively by Yanuka et al (1984) to digitize and analyze other types
of porous media.
According to the Nyquist theorem, 60,000 pixels on a 35 mm x 25 mm image yields
information to a resolution of (2)(35)(25)/60,000 or about 0.03 mm2 which is a square 0.17
mm x 0.17 mm. If the photomicrograph is a 1: 1 image of the section-plane, then this grid
is too coarse for many types of seasonal snow where morphological features of interest are
observed at the O.1 mm scale, and sometimes smaller. A finer scale 512 x 512 pixels seems
preferable, and, in fact, video digitizing cards at that scale are now available for the
IBM PC (and equivalent micros). Perhaps even a finer scale 1024 x 1024 pixels would be
useful for some sections, although handling that quantity of information for -100 serial
sections would be outside the capability of present microcomputers.
Figure 7 provides an example of a section-plane and part of its digital image constructed
with the equipment shown in figure 6.
Figure 6.--Block
diagram of low cost video digitizing
equipment for section-plane analysis.

Figure 7.--Photomicrograph
of section-plane
(top); part of its digital image (bottom).
THREE-PHASE SECTIONS
The distribution of the liquid phase in wet snow is a matter of speculation
since neither thin-sections nor section- planes have been prepared for three-phase
samples. Existing models based on the concept of liquid water surrounding packed spheres
are crude approximations of the interconnected structure.
It is possible to prepare a section-plane from a quasi-three-phase specimen using the
following steps:
1. Start with dry, metamorphosed snow with relatively large grains.
2. Bring the sample to 0 degrees C. Add 0 degrees C water dyed with acid fuchsin to
simulate wet snow.
3. Freeze rapidly with dry ice (liquid nitrogen may be better).
4. Follow steps for section-plane preparation. Allow sublimation, but do not polish the
microtomed surface since that would smear the acid fuchsin.
An example is shown in figure 8. In order to prepare a true three-phase section (rather
than a quasi-section) it is probably necessary to avoid the freezing of the liquid phase
in step 3.
Figure 8.--Section-plane
prepared from
a quasi-three-phase sample. Left grid
marks are 1mm apart.
CONCLUDING REMARKS
Thin-section preparation is slow and tedious. One possibility for a faster technique is to
develop a compliant pore filler such that the section could peel over the microtome knife
as is common practice in histological studies.
The alternative is to use section-planes. Here, the major improvement would be to devise a
technique that accentuates crystal boundaries. A physical discontinuity exists at the
crystal boundary by definition, and it could be possible to observe this discontinuity
using incident, reflected
light.
An important breakthrough would be to develop a technique for preparing three-phase
sections.
LITERATURE CITED
De Hoff, R.T. 1983.
Quantitative serial sectioning analysis: preview. Journal of Microscopy 23(3):259-263.
Fuchs, A. 1959. Some structural properties of Greenland snow. Research Report 42,
24p. U.S. Army Snow Ice and Permafrost Research Establishment, Corps of Engineers,
Wilmette, Illinois.
Good, W. 1979. Metamorphose et parametres structuraux. Institut federal pour
l'etude de la neige et des avalanches. Weisfluhjoch/Davos. Rapport interne 561, 17p.
Good, W. 1980. Structural investigations of snow, a comparison of different
parameter sets. In Gelsema, E.S. and Kanal, L.N. (eds) Pattern Recognition in Practice.
North-Holland Publishing Company: 161-170.
Good, W. 1981. Structure geometrique d'echantillons de neige analyses par un
systeme viedo. Institut federal pour 1'etude de la neige et des avalanches.
Weissfluhioch/Davos. Rapport interne 592.
Good, W. 1982. Structural investigations of snow and ice on Core III from the
drilling on Vernagtferner, Austria, in 1979. Zeitschrift fur Gletscherkunde und
Glazialgeologie 18(1):53-64.
Gubler, H. 1978. Determination of the mean number of bonds per snow grain and of
the dependence of the tensile strength of snow on stereological parameters. Journal of
Glaciology 20(83):329-341.
Keeler, C.M. 1969. Some physical properties of alpine snow. Research Report 271,
74 p. U.S. Army Cold Regions Research and Engineering Laboratory, Hanover, New Hampshire
03755.
Kinosita, S. and G. Wakahama. 1960. Thin sections of deposited snow made by the
use of Analine. Contributions from the Institute of Low Temperature Science No. 15:35-45.
Institute of Low Temperature Science, Hokkaido University, Sapporo, Japan.
Kry, P.R. 1975. Quantitative stereological analysis of grain bonds in snow.
Journal of Glaciology 14(72):467-477.
Narita, H. 1969. Measurement of the specific surface of deposited snow I. Low
Temperature Science Ser. A(27):77- 86.
Perla, R. 1982. Preparation of section planes in snow specimens. Journal of
Glaciology 28(98):199-204.
Sommerfeld, R.A. 1983. A branch grain theory of temperature gradient metamorphism
in snow. Journal of Geophysical Research 88(C2):1484-1494.
Steele, J.H., Jr. 1972. Application of topological concepts in stereology.
Stereology and Quantitative Metallography, ASTM STP 504:39-58.
Weibel, E.R. 1979. Stereological Methods. Vol. 1. Practical Methods for
Biological Morphometry. 415 p. Academic Press, Toronto, Ontario.
Weibel, E.R. 1980. Stereological Methods. Vol. 2. Theoretical Foundations. 340 p.
Academic Press, Toronto, Ontario.
Yanuka, M., F.A.L. Dullien, and D.E. Elrick. 1984. Serial sectioning and
digitization of porous media for two- and three-dimensional analysis and reconstruction.
Journal of Microscopy. Vol. 135, Pt. 2:159-168.
APPENDIX
Supplies and Equipment for
Section-Plane Preparation
There are many combinations of equipment and supplies that can be used in connection with
the preparation of section-planes. The list (below) is not meant to endorse any particular
brands, but represents equipment and supplies
used in our studies.
·*Refrigerated workspace. Evaporator fans baffled by a false ceiling so cold air sinks
gently on workers and equipment. The 2.5m x 2.5m area is well lit, has viewing windows,
and two work benches. Temperature is controllable in the range of 0 degrees C to -20
degrees C with ± 1 degree C fluctuation in long term operation.
* A freezer chest which operates in the refrigerated lab, and maintains storage
temperature of -35 degrees C for long periods.
* Automatic photomacroscope and accessaries: Wild-Leitz M400 optics carrier with drive
housing, built-in camera, and binocular tube. Macro-zoom objective 1 :5. MPS 55 electronic
control. Brightfield/ darkfield base (needed for transmitted light photomicrography, but
not section-plane work).
* Fiber optic ring illuminator (Intralux 150H) compatible with above.
* Base sledge microtome (Leitz model 1400). Cardan object clamp. Two microtome knives
(profile C, wedge shape, 240mm).
* Vacuum cleaner and accessaries (featuring quiet operation at cold temperatures 0 degrees
C to -20 degrees C).
* CO, gas cylinders with siphon attachment.
* Pore filler: dimethyl phthalate (mp 0 degrees C). Good results were obtained using
Matheson, Coleman, and Bell brand.
* Dye: many possibilities. Good results using oil blue N, from Aldrich Chemical Co.
* Fingerprint powder: Good results with Faurot brand "Supersensitive Black".
* Lens tissue (Kodak), cotton swabs, stainless-steel beakers (250-500 ml), shop knife,
small hand-saw, bench clamps, Ektachrome film ET 160, dust masks.
|